Model TWS K105 Load Cell

The Model TWS-K105 is a strain gage load cell that directly replaces the QGPK-105 ABB Pressductor electromagenetic load cell.  The replacement cells will have the same body style and capacities as the ABB cells.  The TechWeigh load cells will replace all these capacities: -6.3 tons to 160 tons.  The load cell utilizes the same cable, so no need for new cable runs.  High temperature compensation andature cable options.

Specifications:
Full Scale Output:  3m V/V
Bridge Resistance:  700 ohms, nominal
Material:  High-Alloy Steel
Temperature:  Range 0 to 150 deg. F  High temperature available to 550 deg. F
Safe Overload:  150%
Maximum Overload:  300%
Combined Error:  0.10% F.S
Non-Repeatability: 0.03% F.S.
Insulation Resistance:  5000 megohms
Standard Cable Length:  25 ft
Color Code:  +Excitation Red, -Excitation Black, +Signal Green, -Signal White
Rated Excitation:  20V AC/DC



Model TWS L105 Load Cell

The Model TWS-L105 is a strain gage load cell that directly replaces the QGPL-105 ABB Pressductor electromagenetic load cell.  The replacement cells will have the same body style and capacities as the ABB cells.  The TechWeigh load cells will replace all these capacities: -5 tons to 160 tons.  The load cell utilizes the same cable, so no need for new cable runs.  High temperature compensation and high temperature cable options.

Specifications:
Full Scale Output:  3m V/V
Bridge Resistance:  700 ohms, nominal
Material:  High-Alloy Steel
Temperature:  Range 0 to 150 deg. F  High temperature available to 550 deg. F
Safe Overload:  150%
Maximum Overload:  300%
Combined Error:  0.10% F.S
Non-Repeatability: 0.03% F.S.
Insulation Resistance:  5000 megohms
Standard Cable Length:  25 ft
Color Code:  +Excitation Red, -Excitation Black, +Signal Green, -Signal White
Rated Excitation:  20V AC/DC

Model TWS 104 Load Cell

The Model TWS-L105 is a strain gage load cell that directly re
places the QGPL-104 ABB Pressductor load cell.  By changing to strain gage technology, any strain gage instrument can now be used with these cells.  The replacement cells will have the same body style and capacities as the ABB cells.  The Techweigh load cell will replace all these capacities:  -10MT to 160 MT.  The load cell utilizes the same mounting arrangement.  No need for any mechanical altercations.  Also utilizes the same cable, so no need for new cable runs.


Specifications:
Full Scale Output:  3m V/V
Bridge Resistance:  700 ohms, nominal
Material:  High-Alloy Steel
Temperature:  Range 0 to 150 deg. F  High temperature available to 550 deg. F
Safe Overload:  150%
Maximum Overload:  300%
Combined Error:  0.10% F.S
Non-Repeatability: 0.03% F.S.
Insulation Resistance:  5000 megohms
Standard Cable Length:  25 ft
Color Code:  +Excitation Red, -Excitation Black, +Signal Green, -Signal White
Rated Excitation:  20V AC/DC
The  model TWS-K105 is a strain gage load cell that directly replaces the QGPK-105 ABB Pressductor electromagnetic load cell.  The replacement cells will have the same body type and capacities as the ABB cells.  The TWS load cells will replace capacities ranging from -6.3T to 160T.  The load cell utilizes the same cable, so no need for new cable runs.  High temperature compensation and high temperature cable options available. 
Model TWS-K105 Load Cell
Specifications:
Full Scale Output:         2mV/V
Bridge Resistance:         700 ohms, nominal
Material:                       High-Alloy Steel
Temperature:                Range 0 to 150 deg. F
                                   High temperature
                                   available to 400 deg. F
Safe Overload:              150%
Maximum Overload:      300%
Rated Excitation:           10V AC/DC         
Combined Error:              0.10% F.S.
Non-Repeatability:            0.03% F.S.
Standard Cable Length:     25 ft.
Color Code:                      + Excitation Red
                                       - Excitation Black
                                       + Signal Green
                                       - Signal White
The Model TWS-K101 is a igh accuracy, strain gage load cell.  The load cell body style and capacities are specifically designed for cran applications. The TWS load cel is available in capacities ranging from 6.3T to 160T.  High temperature construction and high temperature cable options are available up to 400 deg. F.  Custom load cells can be provided to fit specific applications.
Model TWS-K101 Load Cell
Double Ended Shear Beam
Bearing Kits
Load Cell Menu
Canister
Pin Cells
Roll Force
Single Ended Shear Beam
Comptrol Replacements
Model TWS-K102 Load Cell
The Model TWS-K102 is a high accuracy, strain gage load cell.  The load cell body style and capacities are specifically designed for crane applications.  The TWS load cell is available in capacities from 6.3T to 160T.  High temperature construction and high temperature cable options are available up to 400 deg. F.  Custom load cells can be provided to fit specific applications.
For more information regarding our load cells, please contact us at:  mailroom@techweigh.com or Toll Free at:  888-59-WEIGH   (888-599-3444)
Specifications:
Full Scale Output:            3mV/V
Bridge Resistance:            700 ohms, nominal
Combined Error:              0.10% F.S.
Non-Repeatability:            0.03% F.S.
Material:                          High Alloy Steel
Insulation Resistance:       5000 megohms
Standard Cable Length:     25 ft.
Temperature:              Range 0 to 150 deg. F
                                 High temperature
                                  available to 550 deg. F
Safe Overload:             150%
Maximum Overload:     300%
Rated Excitation:          20V AC/DC
Color Code:                 +Excitation Red
                                  - Excitation Black
                                  + Signal Green
                                  - Signal White 
The model TWS-L105 is a strain gage load cell that directly replaces the
QGPL-105 ABB Pressductor electromagnetic load cell.  The replacement cells will have the same body style and capacities as the ABB cells.  The TWS load cell will replace all capacities ranging from -5T to 160T.  High temperature compensation and high temperature cable options available.
Model TWS-L105 Load Cell
TWS-104 Load Cell
The Model TWS-104 is a strain gage load cell that directly replaces the QGPL-104 ABB Pressductor load cell.  By changing to strain
gage technology, any strain gage instrument can now be
used with these cells.  The replacement cells will have the
same body style and capacities:  -10MT to 160MT.  The load
cell utilizes the same mounting arrangement and cables, so no
need for any mechanical alterations or new cable runs. 
Specifications
Full Scale Output:     3mv/V
Bridge Resistance:     700 ohms, nominal
Material:                   High-Alloy Steel
Temperature:            Range 0-150 deg F. 
                               High temperature
                               availbale to 550 deg F.
Safe Overload:          150%
Maximum Overload:  300%
Rated Excitation:       20V AC/DC
Combined Error:     0.10% F.S
Non-Repeatability:   0.03% F.S.
Insulation Resistance:     5000 megohms
Standard Cable Length:   25 ft.
Color Code:                   +Excitation -Red
                                    -Excitation-Black
                                    +Signal-Green
                                    -Signal-White